1. The height of the mixing valve is from the ground The reserved inner wire elbow of the shower is prepared for the next step of loading the mixing valve. Its height is generally between 90-110cm, which can be determined according to the requirements of the owner or the average height of the couple. Out of 110cm, otherwise it will not be able to install the lifting rod shower, not less than 90cm, it is not good to open the valve every time. 2, the spacing of the two inner wire openings Experienced plumbers know that the standard for the spacing of the inner elbows of the shower is that the concealed 15cm error is no more than 5mm, and the surface is 10cm. Remember to be the centering measurement. If it is too wide or too narrow, it will not be installed. Do not rely on adjusting the wire. The adjustment range of the wire adjustment is very limited. 3. After the wall tiles are attached, keep a flat surface with the wall The silk head is reserved. It is necessary to consider the thickness of the wall tile. It is better to make it 15mm higher than the wall of the wall. If it is level with the wall of the blank, you will find that the wire is too deep in the wall. It's not good to put on the shower, but I don't dare to get too much out of the wall. It's too high in the future. The decorative cover can't cover the silk and adjust the screws. 4, pay attention to different styles of shower Nowadays, the quality of people's lives is constantly improving, and the styles of showers that come into being are also varied. The installation methods are not the same. There are mounted, concealed, wall-mounted, ceiling-mounted, as hydropower workers. Constantly learn and master the new product installation methods on the market. 5, choose the location is very important The shower is a bathing device. When people are taking a bath, they are not wearing clothes. Therefore, when choosing a shower, you should pay attention to its privacy. Generally, do not choose to be at the door or window. In addition, if there is a whole bath room, fully Communicate with the owner to see the size of the overall bath room. Look at the location of the shower mixing valve. Don’t wait for the decoration. After the bath room is bought, the position is not suitable for the wall. The guerrillas usually touch it. In this case, it is not that you do not answer the phone or you are missing, or that I am not in Zhengzhou, etc. 6, left hot right cold can not be wrong The inner elbow outlet of the shower should be mastered. The left hot right cold can't be wrong. This is not only the national norm and the habits of the majority of the owners. What is more important is that the manufacturers' products are also produced according to the left hot right cold regulation. If you make a mistake, it may cause some devices to not work, or damage the device. This should be noted when the pipeline is laid. 7. Fixing the inner wire elbow The fixing of the inner wire elbow is very important. If it is not fixed, the size cannot be positioned. It is very likely that the mixing valve will not be installed after the decoration. This is the case in the Tuscan community. The shower can't be installed, and the water and electrician is called. The plumber confidently said that I have been working on water and electricity for 3 years. I don't know, I have a good size of 15cm, which is definitely a mistake. Please believe that the statement in front of him is correct. The latter sentence can be used to smash the master of the wall tile. Does the master of the wall tile need to move his pipe? It is definitely not fixed. |